XMP44
SourceCon™ professional modular audio system
Highlights
- Fully flexible modular structure
- 4 x SourceCon™ interface card slots
- 2.8" LCD display with intuitive user interface
- Wide variation of modules separately available
- Front USB interface for each module (4x)
- Remote control web interface (HTML5)
- RS232 & TCP/IP control port
- Front PFL speaker with vol. control
- Simutaneous operation for all modules
Applications
- null
- null
- Education
- Clubs
- Retail
- Houses of worship
The XMP44 is a professional modular audio system with 4 SourceCon™ interface card slots where to a wide variation of optional modules can be installed. The variety of available modules ranges from FM tuners to DAB&DAB+ tuners, internet radio tuners, voice file interfaces and many more. The flexible architecture allows any project combination up to four sources, resulting in a truly versatile solution that will live up the needs for any user taking high regard of crystal clear audio reproduction. Simultaneous operation for all four modules makes it a compact multi-source system which is the perfect expansion for any multi-zone audio system. The front panel of the system accommodates a 2.8” TFT display in combination with a push rotary function dial and 4 tactile pushbuttons. The controls and indicators on the front panel of the unit are guaranteeing an intuitive and user friendly operation, allowing hassle free operation and configuration to even unexperienced users. Four USB interfaces (one for each module) are enabling playback or storage of media and voice file, while pre-listening for each output is possible through a built-in PFL speaker with individual volume control. Both RS-232 and TCP/IP communication ports are implemented, allowing system integration with any home or industrial automation system. Using the freely available AUDAC Touch™ application for smart devices guarantees total system control and configuration from any device on any location and at any time. An optional Dante™ interface is available for the XMP44. The installation of this network interface allows receiving and sending of low latency, high quality audio over a standard Ethernet network.
Choose your native platform and get started!
System specifications | ||||
---|---|---|---|---|
Inputs | Type | 4 x SourceCon™ interface card slots | ||
4 x USB interface | ||||
Control | Front panel | |||
RS-232 | ||||
TCP/IP | ||||
Audac Touch™ | ||||
Web (HTML5) | ||||
Frequency | Response (± 3 dB) | 20 Hz - 20 kHz | ||
Display | Type | 2.8” Graphical LCD | ||
Monitoring | Front PFL speaker with vol control | |||
Power | Source | 110 ~ 240 V AC / 50 ~ 60 Hz | ||
Consumption | 2 W (without module installed) | |||
Supply | Switching mode | |||
Operating temperature | 0° ~ 40° @ 95% Humidity | |||
Socket Connections (AUDAC Touch™) | 4 sockets |
Product Features | ||||
---|---|---|---|---|
Dimensions | 18.98 x 1.73 x 12.99 " (W x H x D) | |||
Weight | 7.50 lb | |||
Mounting | 19” | |||
Unit height | 1 HE | |||
Construction | Steel | |||
Colours | Black |
AUDAC Touch™
Dante setup
Decentralized TouchLink™ shop setup
Click here to learn more about this example.
NCP105 is controlling the outputs of NWP300 in this example.
You can control the MFA series and AMP203 through the commander functionality. Click here to see how you can do it.
Centralized company setup
Bar & restaurant setup
Meeting room setup
Product
Answer
Any product that is updatable by the AUDAC system manager is automatically discovered and downloaded to your personal computer.
All other software versions can be found via audac.eu/software
Previous firmware versions can be found in the portal on the support tab.
Answer
Yes, it is always recommended to run the latest firmware to be compatible with AT2.
Answer
When the user password is lost, it can be changed by logging in with the administrator password. When the administrator password is lost, please contact your local distributor.
Answer
Please download the AUDAC system manger. This will scan your network and tell you the IP address of all AUDAC products within your network.
If your network is blocking global broadcasts, you can connect directly by using a cross cable. The system manager will still be able to inform you of the device IP.
Answer
AUDAC uses two methods to update their devices.
- USB
- AUDAC system manger
When unsure which method to use, please refer the product manual.
Answer
When connecting directly to the product,
- Ensure you are using a cross-link network cable
- Ensure your personal computer is within the same default AUDAC IP range 192.168.0.xxx
- Check the WIFI settings of your laptop. In many cases, the laptop will try to make a priority connection through the WIFI network, whereby it will be impossible to reach the webserver. After the WIFI connection of the laptop is disabled, it will work properly
When connecting to your product via network
- Ensure your personal computer is within the same default AUDAC IP range 192.168.0.xxx
When trying to connect with a personal media device.
- Ensure the tablet/pad is within range of both the WiFi and AUDAC IP range.
Information sheet English
Create a document that summarizes all the details of this product. The product information sheet can contain: product descriptions, technical drawings, technical specifications, architect’s and engineer’s specifications, shipping and ordering details, product applications, ...
Information sheets other languages
Technical drawings
Service documentation
Software
Firmware
Declarations of conformity
Code | Quantity | Length | Width | Height | Cubage | Weight |
---|---|---|---|---|---|---|
PRODUCT | 1 | 0,48 m | 0,46 m | 0,04 m | 0,00971 m³ | 3,69 kg |
PCS | 1 | 0,57 m | 0,43 m | 0,13 m | 0,03037 m³ | 4,52 kg |
INNER | 1 | - | - | - | - | - |
MASTER | 1 | - | - | - | - | - |
PALLET | 34 | - | - | - | - | 156,00 kg |